  • The brace consists of a foot component and a lower leg component joined by a brace ankle joint.
400,00 EUR
incl. VAT / piece
Regular price / piece
Model
Size
You can also buy using:
Pre-order
Pre-order
Safe shopping
Product sold out
You will receive an email notification from us when the product is available again.
Data is processed in accordance with the privacy policy. By submitting data, you accept privacy policy provisions.
Contact details entered above are not used to send newsletters or other advertisements. When you sign up to be notified, you hereby agree to receive only a one-time notification of a product re-availability.

The brace consists of a foot component and a lower leg component joined by a brace ankle joint. The foot component consists of a sole that can be cut to size and a foot stirrup. The lower leg component consists of the brace ankle joint, the bars and the calf shell with the strap. Adjustments to the brace are made by angling the bars.

 

The brace is intended exclusively for orthotic fittings of the lower limbs and exclusively for contact with intact skin.
The brace must be used in accordance with the indications.

Indications:

  • Unicompartmental knee osteoarthritis
  • Bicompartmental osteoarthritis of the knee
  • Conditions/injuries requiring unicompartmental relief (e.g. post-operative treatment following meniscus reconstruction or ligament injuries which require unilateral relief)
  • The indication must be determined by the physician. The following indications require consultation with a physician: skin dis­ eases/injuries; inflammation; prominent, swollen scars; reddening and hyperthermia of the treated limb; pronounced varicose veins, especially with impaired return flow; lymphatic flow disorders, including unclear soft tissue swelling distal to the body area where the device will be applied; sensory and circulatory disorders in the legs, e. g. associated with diabetic neuropa­ thy.

The product is designed for a maximum lifetime of 2 years.

Mechanism of Action:

The brace reduces the varus or valgus moment on the knee joint depending on the selected brace.
Two mechanisms influence the extent of the varus moment on the knee joint. The rigid bridging of the ankle joint in the frontal plane initially reduces ever
sion in the lower ankle joint. Adjustable forces are simultaneously transferred to the lower leg region at the lateral contact point of the brace.

In the treatment of medial osteoarthritis of the knee (brace bar lateral), this effect shifts the vector of the ground reaction force laterally. This immediately results in the reduction of the varus moment in the knee joint and relief for the medial compartment. In the treatment of lateral osteoarthritis of the knee (brace bar medial), the force transmission point is shifted in the medial direction. This increases the varus moment and reduces the valgus moment in the knee joint, relieving the lateral compartment. Strain can be relieved on either the lateral or medial compartment, depending on the selected brace.

 

Selecting the size:

Determine the height of the lateral malleolus, including existing orthope­ dic insoles. Select the appropriate brace size.
Verify that the calf shell is at least 3 cm below the fibular head. If the calf shell extends closer to the fibular head, select the next smaller brace size.  
The product may only be molded by qualified personnel. Do not make any improper changes to the product. Always apply the product according to the information in the instruc­ tions.

 

Symbol
50K4=3
This is a medical device
Use it according to the instructions for use or label.
Do you need help? Do you have any questions?Ask a question and we'll respond promptly, publishing the most interesting questions and answers for others.
Ask a question
If this description is not sufficient, please send us a question to this product. We will reply as soon as possible. Data is processed in accordance with the privacy policy. By submitting data, you accept privacy policy provisions.
Write your opinion
Your opinion:
5/5
Add your own product photo:
SizeLateral Joint Height
S Left63 - 72 mm / 2,5 - 2,8 inch
S Right63 - 72 mm / 2,5 - 2,8 inch
M Left73 - 82 mm / 2,9 - 3,2 inch
M Right73 - 82 mm / 2,9 - 3,2 inch
L Left83 - 92 mm / 3,3 - 3,6 inch
L Right83 - 92 mm / 3,3 - 3,6 inch
XL Left93 - 103 mm / 3,7 - 4,1 inch
XL Right93 - 103 mm / 3,7 - 4,1 inch

  1. Determine the height of the lateral malleolus, including existing orthope­ dic insoles. Select the appropriate brace size (see sizing table, see page 5-6).

  2. Verify that the calf shell is at least 3 cm below the fibular head. If the calf shell extends closer to the fibular head, select the next smaller brace size.